top of page
B Braun Sangofix Air Blood Administration Set - Vented

B Braun Sangofix Air Blood Administration Set - Vented

SKU: SMB-I147-4/4080187
$79,47Preço

- The B Braun Sangofix is a vented blood administration set for the administration of blood and blood components stored in glass bottles for gravity administration

- The device can be used for all patients for which infusion therapy is prescribed. Sangofix can be used for adults, paediatric and neonate patients

- The blood filter with 11 cm2 surface area helps to prevent particulate contamination by retaining particles >200 ? and consequently helps to avoid transfusion of blood clots and cellular debris resulting from storage

- During a laboratory test, Sangofix with a filter surface of 11 cm2 was used to successively administer 10 erythrocyte concentrates while providing a higher flow rate than required by ISO 1135-4

- The blood administration set has a clear, vented piercing spike with sharp tip for use with glass bottles

- Its fully transparent dome offers visibility for a constant visual monitoring of flow rate

- Its elastic pump chamber allows easy and quick set-up of fluid level

- The blood transfusion set has a bacteria-tight air vent, closable with handy snap cap

- The BT set features a screw tight Luer Lock patient connector which helps to avoid accidental disconnection which could lead to microbiological contamination

- The blood administration set comes with a needle size of 18G with a needle length of 1.5 inch

- The latex free BT set is pressure resistant up to 400 mm Hg. (approx. 0.5 bar)

- Directions for Use:

- Gather general equipment and a tray disposal

- Close roller clamp

- Remove protective cap from spike

- Insert spike into blood bag. Use white ring as finger stopper.

- Priming of blood administration set:

- Hang blood bag on stand and attach patient connector to hook of roller clamp housing

- Gently squeeze bottom part of the drip chamber and fill fluid level up to white ring

- Make sure that filter surface - inside and outside - is completely wetted

- Open roller clamp and prime Sangofix until free of air

- Close roller clamp

- Patient connection:

- Remove PrimeStop cap

- Then move collar of Spin-Lock Connector backwards to activate its rotating function

- Move collar forward and screw it clockwise onto the Caresite extension set

- Start blood transfusion:

- Open roller clamp and adjust flow rate

- Control drop rate during transfusion

- To interrupt or stop transfusion, close roller clamp

- How to disconnect:

- Unscrew the collar of Spin-Lock Connector counter-clockwise

- Then move collar backwards up to stop position

- Turn collar counter-clockwise to disconnect from Caresite extension set

(For orders above US $300 only)

Produtos relacionados

bottom of page